Curve Tracer Adaptor
The scope display thus represents an X-Y graph where voltage across a circuit under test is displayed on the X axis (horizontal) and the current though it displayed on the Y axis (vertical). With a calibrated scope this equates to 1mA/V. IC1 and a relay are included to enable two probes to be used and comparisons made between a known good device and a faulty one. The relay should be a low capacitance reed type. By using the scope’s X and Y gain controls, the sinewave applied to the device under test should be adjustable from a few millivolts up to 24V peak-peak to get a very useable display.
Thus, the unit can be used on voltage sensitive devices and at the other end of the scale apply enough voltage to check the operation of, say, a 10V zener diode. Note that all devices should be tested in the unpowered condition. If used for in-circuit tests, the effects of circuit components will need to be taken into account. Shielded coax leads should be used for the X and Y inputs and the probe leads should have zero resistance. Normal scope probes should not be used as these usually have significant built-in resistance which will interfere with measurements.