Light-Controlled Pond Pump
With no light on the photocell, the voltage on the base of Q1 is greater than 0.6V and therefore it is switched on. When light falls on the photocell, its resistance decreases, lowering the bias voltage on Q1 and switching it off. This in turn allows Q2 to switch on, energised the relay and turning on the pond pump. In use, the 2.2MΩ trimpot is adjusted so that the pump cuts out at the desired light level. A 47μ F capacitor across LDR1 prevents transient light changes from affecting circuit operation. S1 is a miniature SPDT centre-off toggle switch, allowing the pump to be turned on or off manually, or switched to automatic mode. The circuit was constructed on a small protoboard from Dick Smith Electronics (Cat. H 5604) and housed in a bulkhead box, which was then attached to the transformer housing. The photocell was soldered to a length of figure-8 cable and sheathed in a short length of heatshrink tubing to form a light probe. This was attached to a nearby fence post to provide suitable exposure to sunlight.