Saturday, June 19, 2010
Mains Failure Alarm
When the mains power disappears, Re1 is de-energized and the 0.22 F Gold-cap used in position C4 provides supply current to IC2. When the mains voltage is present, C4 is charged up to about 5.5 volts with IC1 acting as a 100-mA current limit and D10 preventing current flowing back into the regulator output when the mains voltage is gone. According to the Goldcap manufacturer, current limiting is not necessary during charging but it is included here for the security’s sake. The CMOS 555 is configured in astable multivibrator mode here to save power, and so enable the audible alarm to sound as long as possible. Resistors R5 and R6 define a short ‘on’ time of just 10 ms. That is, however, sufficient to get a loud warning from the active buzzer. In case the pulses are too short, increase the value of R5 (at the expense of a higher average current drawn from the Goldcap).