Model Theatre Lighting Dimmer
The length of this period is set by capacitor C2 and the combination of resistors R6 with pots VR1 and VR2. The output of IC1 at pin 3 is then fed to transistor Q5 which inverts this signal to trigger the Triac via a 100# resistor. When the timing period is short, the Triac is turned on early in half cycle and lights are bright. Conversely, when the timing period is longer, the lights are dim or turned off. The main dimmer control is potentiometer VR1. Trimpot VR1 is used to set the range of VR1. With VR1 set fully clockwise (ie, maximum resistance) trimpot VR2 is adjusted until the lights are just turned off. The lights should then be able to be faded over the full range by the control potentiometer.